Sensors Shelly troubleshooting
Shelly Add-on temperature sensor shows no reading
A DS18B20 probe on the Plus Add-on shows N/A, never appears, or reads the wrong number. Check the Add-on is switched on, the probe is added, and where the Shelly sits.
- Gen4
Start here
What are you seeing?
Pick the closest match and we'll point you to the fix most likely to sort it.
Why it happens
The Plus Add-on clips onto a Shelly 1, 1PM or 2PM Gen4 and reads up to five DS18B20 temperature probes. The relay has to be told the Add-on is there, and each probe added on its own.
When a probe shows N/A, the Shelly knows about it but can't get a reading. That comes down to the probe, its connections or the heat around the Shelly.
These checks are done on the device's web page or in the app. The Add-on plugs onto a relay that carries mains, so checking or reseating it, or the probe's connections, is a job for a licensed electrician with the power off. Don't open the wall plate.
Quick checks first
Run these checks before moving on to the fixes.
On its web page, click Add-on. Your probes are listed under Peripherals, each with its reading. N/A with a red read tag means no reading.
Shelly rates the relay and the Add-on for up to 40 °C around them. Only the probe belongs in a roof space or other hot spot.
Fixes, most likely first
Work down the list and stop when it's fixed.
- Most likely for you
The Shelly can't read the probe
How to tell. The probe is listed under Peripherals but shows N/A. Shelly says N/A means the sensor can't retrieve a value or isn't working properly.- Restart the device
On its web page, go to Settings and click Reboot, then check the reading again.
- Check it isn't overheating
If the relay and Add-on sit in the roof space with the probe, they're outside their 40 °C rating on a hot day. Moving them is a job for a licensed electrician; only the probe needs to stay in the roof.
- Ask an electrician to check the connections
If it still shows N/A, the Add-on's seating, the probe's connections or the probe itself need checking with the power off. That's a job for a licensed electrician.
Did this fix it? - Restart the device
- Most likely for you
The Add-on isn't switched on
How to tell. The Add-on page has None picked, and there's no Peripherals section to add a probe to. The device only uses the Add-on once it's enabled and restarted.- Choose Sensor Add-on
On its web page, click Add-on, pick Sensor Add-on and click Save and reboot. In the app, it's the Add-on peripherals tab.
Did this fix it? - Choose Sensor Add-on
- Most likely for you
The probe was never added
How to tell. The Add-on is on, but the probe isn't listed. Switching the Add-on on doesn't create any sensors; each probe is added on its own.- Add the probe
On the Add-on page, click the + beside Peripherals, choose the DS18B20 temperature sensor, tick the probe it finds (Rescan if it doesn't), then add it and reboot.
- One at a time in the app
The app adds one peripheral at a time, with a restart after each.
Did this fix it? - Add the probe
- Most likely for you
A new probe replaced the old one
How to tell. After swapping a probe, the old entry shows N/A. Each entry is tied to one probe's address, so a new probe isn't linked to it.- Note its settings first
Shelly warns that deleting a peripheral removes it and all its actions for good. Note its name, offset and any actions first.
- Delete the old entry and add the new probe
On the Add-on page, click the bin beside the old entry. Then click the + beside Peripherals to add the new probe, and reboot.
Did this fix it? - Note its settings first
- Most likely for you
A DHT22 is set up as well
How to tell. A scan for DS18B20 probes finds nothing while a DHT22 humidity sensor is set up. Shelly supports up to five DS18B20 probes or one DHT22, not both.- Pick one type
Delete the DHT22 entry and reboot before scanning for DS18B20 probes. Rewiring between the two is a job for a licensed electrician.
Did this fix it? - Pick one type
- Most likely for you
The offset or threshold is off
How to tell. A reading shows but it's shifted, or it won't change until the temperature moves a lot. Offset adds to every reading, and the threshold sets how far it must move before it reports.- Check Offset and Delta Threshold
On the Add-on page, click the pencil beside the probe. Set Offset to 0 unless you added it on purpose. Delta Threshold runs from 0.1 to 5 °C; a low value reports smaller changes.
Did this fix it? - Check Offset and Delta Threshold
- Most likely for you
The model doesn't take the Add-on
How to tell. There's no Add-on page at all. Shelly lists the 1, 1PM and 2PM Gen4 as Plus Add-on hosts. The Dimmer Gen4 is not supported, and the Mini models aren't on the list.- Use a supported host, or another sensor
A Plus Uni takes the same probes on low voltage, or a BLU H&T reports temperature with no wiring. Changing the device is a job for a licensed electrician.
Did this fix it? - Use a supported host, or another sensor